Precautions For The Use Of Ultrasonic Homogenizer
Jan 06, 2023
Ultrasonic Homogenizer is mainly composed of driving power,bracket,reactor,ultrasonic converter,transmitter,and variable bar.Ultrasonic average machines are used in the fields of pharmaceuticals,biology,nano,chemical,dyes,optical,jewelry,aerospace,hardware,and automobile manufacturing.
The working principle of the ultrasonic homogeneous machine is to achieve the average quality effect by using the empty effect of ultrasonic in the liquid and other physical effects.Among them,the empty effect refers to That is,small bubbles,small bubbles with ultrasound,and the acupuncture will collapse within a sound cycle.Ultrasonication can also produce a strong mechanical effect,generating fast shot or sound flow near the solid interface,and a strong shock wave in the liquid.The physical function refers to the structure of the ultrasonic that can form an effective stirring and the structure of the flow destruction medium in the liquid,and the particles in the crushing liquid.It is mainly a change in the surface of the particles in the liquid collision,micro-phase flow,and shock waves.
Precautions for the use of Ultrasonic Homogenizer:
1.Before starting,it should be fully inspected whether the coexistence of each solid part and pipeline should be strong and reliable;
2.Inject clean mechanical oil into the power box to the oil level line;
3.Put connect the plunger cooling water,and use the water to form a thin line;
4.Check the oil regularly,change the oil for 100 hours for the new machine,and change it every 1,000 hours in the future;
5.Check the rotation of the belt,and the reverse rotation is strictly prohibited at work;
6.It is strictly forbidden to start with pressure;
7.After starting the pressure table,if the pressure table is beating violently or the pressure does not go up,the pressure gauge will be zero and then loosen the open gas device screw until the air bubble overflows,and then the screw is tightened.
8.After starting,it should be gradually adjusted to the required pressure to avoid impact caused by stress mutations;
9.When running the load,the work pressure cannot exceed the rated pressure value;
10.Press the average pine regulating handle before parking to remove the pressure.After the machine is stopped,the valve on the feed pipe is turned off.